Lifting Equipment Inspection

Equipment types and standards

We are able to provide you with inspections that meet today's standards and meet the requirements of the most demanding sites.

Mobile cranes

Mobile cranes

Typically applied standards and recurrences :   CSA Z150 - 20 (Par. 5.3.5): Structural inspection once a year Safety Act - Nunavut - Part...

Typically applied standards and recurrences :

 

  • CSA Z150 - 20 (Par. 5.3.5): Structural inspection once a year
  • Safety Act - Nunavut - Part 13: Inspection every 2 years or 1800 hrs

 

Inspections typically performed :

 

  • Visual structural inspection and magnetic particle inspection as needed
  • Functional tests (including limiters)
  • Verification of security elements
  • Ultrasonic axis inspections
  • Visual inspection of accessible electrical and hydraulic components
  • Lifting test with load

 

Deliverables :

 

  • Inspection certificate signed and sealed by an engineer
  • Detailed visual inspection report with checklist
  • Report for tests carried out (magnetic particle inspection, ultrasound)

Mobile lifting platforms

Mobile lifting platforms

Typically applied standard and recurrence :   CSA B354.7 - 2017 (Par. 5.2.6): Structural inspection after 10 years, and every 5 years thereafter   Inspections...

Typically applied standard and recurrence :

 

  • CSA B354.7 - 2017 (Par. 5.2.6): Structural inspection after 10 years, and every 5 years thereafter

 

Inspections typically performed :

 

  • Visual structural inspection and magnetic particle / penetrant testing as needed
  • Operational tests
  • Verification of security elements
  • Ultrasonic axis inspections
  • Visual inspection of accessible electrical and hydraulic components

 

Deliverables :

 

  • Inspection certificate signed and sealed by an engineer
  • Detailed visual inspection report with checklist
  • Report for tests carried out (magnetic particle inspection, ultrasound or penetrant testing)

Concrete pump trucks

Concrete pump trucks

Typically applied standard and recurrence :   Occupational Health and Safety Act, S-2.1, r. 9, Articles 57: Inspection of load-bearing parts...

Typically applied standard and recurrence :

 

  • Occupational Health and Safety Act, S-2.1, r. 9, Articles 57: Inspection of load-bearing parts after 5 years or 6000 hrs, and every 3 years or 6000 hrs thereafter.
  • Occupational Health and Safety Act, S-2.1, r. 9, Articles 56: General inspection every year or 1500 hrs

 

Inspections typically performed :

 

  • Visual structural inspection and magnetic particle inspection as needed
  • Operational tests
  • Verification of security elements
  • Ultrasonic axis inspections
  • Visual inspection of accessible electrical and hydraulic components

 

Deliverables :

 

  • Inspection certificate signed and sealed by an engineer 
  • Detailed visual inspection report with checklist
  • Report for tests carried out (magnetic particle inspection, ultrasound)

Workers lifting baskets

Workers lifting baskets

Typically applied standard :   Hanging baskets according to CSA, Z150-20 Hanging baskets in accordance with Safety Code S2.1, r.6, art.3.10.7.2 Fixed...

Typically applied standard :

 

  • Hanging baskets according to CSA, Z150-20
  • Hanging baskets in accordance with Safety Code S2.1, r.6, art.3.10.7.2
  • Fixed baskets according to CSA B335-15, par. 4.9.9

 

Inspections typically performed :

 

  • Visual structural inspection and magnetic particle inspection as needed
  • Verification of security elements
  • Conformity to sealed manufacturing drawing

 

Deliverables :

 

  • Inspection certificate signed by an engineer 
  • Detailed visual inspection report with checklist
  • Report for tests carried out (magnetic particle inspection) 

Rough terrain forklifts

Rough terrain forklifts

Typically applied standard and recurrence :   CSA, B335-15: Annual inspection or 2000 hrs   Inspections typically performed :   Visual...

Typically applied standard and recurrence :

 

  • CSA, B335-15: Annual inspection or 2000 hrs

 

Inspections typically performed :

 

  • Visual structural inspection and magnetic particle inspection as needed
  • Operational tests
  • Verification of security elements
  • Ultrasonic axis inspections
  • Visual inspection of accessible electrical and hydraulic components
  • Lift test

 

Deliverables :

 

  • Inspection certificate signed by an engineer 
  • Detailed inspection report with checklist
  • Report for tests carried out (magnetic particle inspection, ultrasound)

Hooks

Hooks

Typically applied standard :    ASME, B30.10 - 2019, Minimum once a year.   Inspections typically performed :   Visual inspection...

Typically applied standard :

 

  •  ASME, B30.10 - 2019, Minimum once a year.

 

Inspections typically performed :

 

  • Visual inspection and magnetic particle inspection
  • Verification of required elements (identification, capacity, valve)
  • Presence of modifications

 

Deliverables :

 

  • Detailed visual inspection report with checklist
  • Report for tests carried out (magnetic particle inspection)

Lifting accessories

Lifting accessories

Typically applied standard :   ASME, B30.20 - 2018, Minimum once a year, depending on the type of service.   Inspections typically performed...

Typically applied standard :

 

  • ASME, B30.20 - 2018, Minimum once a year, depending on the type of service.

 

Inspections typically performed :

 

  • Visual and magnetic particle inspection
  • Conformity to design drawing

 

Deliverables :

 

  • Detailed visual inspection report
  • Report for tests carried out (magnetic particle inspection)

Personnel certifications

  • Welding inspectors, levels 1, 2, 3
  • NDT technicians: CGSB MT, PT, UT, levels 1 and 2
  • Engineers (OIQ, PEO, NAPEG)

Presence on OSH platforms

Presence on OSH platforms
Presence on OSH platforms
Presence on OSH platforms